Strengthening a bathroom floor on Bethlehemweg in Utrecht
During the bathroom renovation, the contractor noticed excessive deflection of the timber joists and asked De VerbouwingsConstructeur for advice. We found: Undersized timber joists: 70×150 mm over a span of 4,500 mm, with varying centres of up to 600 mm. In the […]